LEADERS IN SECURITY ELECTRIC FENCING PRODUCTS

Home page
About Us
Our Products
Nemtek Fence-Probe
Why electric fencing
Electric Fence Training
Contact Us
Photo Gallery
Customer satisfaction survey
User and technical manuals
Disclaimer
Nemtek Bill Of Materials
Nemtek ISO 9001:2000 certificate



Master Control Energizers 20 Zone System


Merlin Stealth Energizer Master M25S Merlin Stealth Energizer ™ Master M25S:

Enables up to 10 Dual Zone energizers to be networked and controlled as a 20 zone electric fence system

Merlin Stealth Master Keypad
Merlin Stealth Master Energizer Tech Manual Technical Manuals
Merlin Stealth Master Energizer Electronic Brochure Electronic Brochure
Merlin Stealth Master Energizer CE Certificate CE Certificate
A modular building system which offers a simple solutions to complex security fencing needs
A flexible zoning solution for medium to high security electric fencing
Configurable to be part of a networked security system
Increased security by independent energizers acting as one complete sophisticated system
Compliant with IEC 60335-2-76
4.8 Joule typical output energy (500 ohms at max setting)


Merlin Stealth Energizer Master M28S Merlin Stealth Energizer ™ Master M28S:

Enables up to 10 Dual Zone energizers to be networked and controlled as a 20 zone electric fence system

Merlin Stealth Master Keypad
Merlin Stealth Master Energizer Tech Manual Technical Manuals
Merlin Stealth Master Energizer Electronic Brochure Electronic Brochure
Merlin Stealth Master Energizer CE Certificate CE Certificate
A modular building system which offers a simple solutions to complex security fencing needs
A flexible zoning solution for medium to high security electric fencing
Configurable to be part of a networked security system
Increased security by independent energizers acting as one complete sophisticated system
Compliant with IEC 60335-2-76
7,6 Joule typical output energy (500 ohms at max setting)


20 Zone Merlin Stealth Master Keypad 20 Zone Merlin Stealth Master Keypad:

The 20 zone keypad, can control the entire system
Global commands and energizer specific commands can be given
Up to 4 keypads can be configured onto the Master energizers


Merlin Stealth Master Keypad Tech Manual Technical Manuals


Merlin Stealth RS485/RS232 Converter Board Merlin Stealth ™ RS485/RS232 Converter Board:

The Merlin Stealth RS485/RS232 converter board, enables communication up to 1200m between energizers.

Copper cable is used with this type of converter




Merlin Stealth Fiber-Optic RS485/RS232 Converter Board Merlin Stealth ™ Fiber-Optic RS485/RS232 Converter Board:

Merlin Stealth Fiber-Optic RS485/RS232 converter board, enables communication up to 3000m between energizers.

Fiber optics is the medium of choice.




Merlin Mimic Panel Merlin Mimic Panel:

Merlin Mimic Panel can provide 16 programmable outputs.

Merlin Mimic Panel, for the Merlin Stealth Energizer ™ 20 zone keypad bus.

Merlin Mimic Panel, for the Merlin Stealth Energizer ™ RS485 bus.




Nemtek Security Energizers - Power Specifications at a glance

Druid Wizord Merlin Merlin Stealth Energizers
Nemtek Energizer Models Druid Wiz4 Mer4 M15S M18S M25S and Master M25S M28S and Master M28S M113S
Typical output energy into a 500 Ohms load on maximum setting: ** (M113S maximum energy into a 210 Ohms load) 2J **** 3.7J **** 3.7J **** 4.8J **** 7.6J **** 4.8J **** 7.6J **** 7.0J ****
12.7J into 210 Ohms
Typical voltage on an open circuit on maximum setting: 7400V 8000V 8000V 8500V 9300V 8500V 9300V 8400V
Typical voltage on a load of 500 Ohms on maximum setting: 6100V 7000V 7000V 5600V 7600V 5600V 7600V 5500V
Battery lead acid maintenance free: 7AH 7AH 7AH 7AH 7AH 7AH 7AH 7AH
Typical standby time * (with a fully charged new battery) 24 hrs 36 hrs 24 hrs 5-6 hrs 8-9 hrs 6-8 hrs 5-8 hrs 7-8 hrs
Typical power consumption, main supply on and a fully charged battery: 17VA 18VA 16VA 27VA 23VA 27VA 25VA 32VA
Typical power consumption, main supply off, running on battery supply only (during a power failure): 8W 10W 10W 17W 20W 17W 20W 20W
Typical power consumption, mains supply on, at maximum joule while charging battery (flat bettery): 19VA 24VA 24VA 33VA 47VA 36VA 47VA 53VA
Nemtek Recommended live wire length *** Galvanised braided 1.2m: up to
2km
up to
3km
up to
3km
up to
8km
up to
10km
up to
2x4km
up to
2x5km
up to
15km
Galvanised solid 2.24mm: up to
3km
up to
4km
up to
4km
up to
16km
up to
20km
up to
2x8km
up to
2x10km
up to
20km
Stainless steel solid 1mm (304 & 316): up to
0.5km
up to
0.6km
up to
0.6km
up to
0.7km
up to
0.8km
up to
2x0.7km
up to
2x0.8km
up to
0.8km
Stainless steel solid and braided 1.2mm (304 & 316): up to
0.6km
up to
0.7km
up to
0.7km
up to
0.8km
up to
1km
up to
2x0.8km
up to
2x1km
up to
1km
Aluminium solid 1.6mm and 2.0mm: up to
6km
up to
8km
up to
8km
up to
32km
up to
40km
up to
2x16km
up to
2x20km
up to
40km
Maximum live
wire length ***
Galvanised braided 1.2mm: 4km 5km 5km 18km 25km 2x9km 2x13km 35km
Galvanised solid 2.24mm: 6km 10km 10km 35km 50km 2x17km 2x25km 50km
Stainless steel solid 1mm (304 & 316): 0.6km 0.9km 0.9km 1km 1.2km 2x1km 2x1.2km 1.2km
Stainless steel solid and braided 1.2mm (304 & 316): 0.7km 1km 1km 1.1km 1.3km 2x1.1km 2x1.3km 1.3km
Aluminium solid 1.6mm and 2.0mm: 12km 16km 16km 60km 80km 2x30km 2x40km 80km
Weight incl. battery weight: 5.9 kg 5.9 kg 6.1 kg 7.7 kg 7.7 kg 7.7 kg 7.7 kg 7.7 kg
Dimensions Length: 275mm 275mm 275mm 365mm 365mm 365mm 365mm 365mm
Dimensions Breadth: 205mm 205mm 205mm 235mm 235mm 235mm 235mm 235mm
Dimensions Height: 110mm 110mm 110mm 140mm 140mm 140mm 140mm 140mm

All mains (220 VAC) energizers can be manufactured for 110 VAC. Specifications can change without prior notice
* Standby time is a function of the battery condition and energizer settings. In HV mode, different energizer models may switch to LV mode and increase the battery life.
** Typical output energy is a function of component tolerance and energizer settings.
*** Recommended and maximum live wire length could be affected by external factors. If loop monitoring is used then the total length of both live and earth series wires must be taken into account.
**** Output energy is reduced under mains failure conditions.